EXAPATH NAIL PLATE KIT (EXNPSG-00)
 eXapath multi-purpose Nail Plate (EXNPSG-00)


When installing the eXapathTM low voltage cable pathway system you'll need to consider line voltage electrical wires. In general line voltage and low voltage cables should cross paths perpendicular to each other as a means of minimizing communications interference.
For walls less than 6 inches deep:
- Creating a horizontal pathway for line voltage wiring.
- For best results use a 7/8" Brad Point drill.
- Create the path by using the built-in sidewall v-groove as a pilot hole.
- Add an eXapath multi-purpose Nail Plate (EXNPSG-00) to protect installed wiring.
- For additional stability fasten the nail plate to adjacent stud of blocking using holes provided.
Exterior walls of 6 inch depth or greater:
- Route the line voltage wiring between the eXapath conduit and wall sheathing.
- Provide at least 1 1/4" space between the cable and the sheathing (check with building officials for local codes).
- Line voltage wire may also be routed according to the recommendations above (walls less than 6 inches deep).