EXAPATH NAIL PLATE KIT (EXNPSG-00)

eXapath multi-purpose Nail Plate (EXNPSG-00)

eXapath Nail Plate and Framing

 

 

 

 

 

 

When installing the eXapath® in-wall cable pathway system you'll need to consider line voltage electrical wires.  In general line voltage and low voltage cables should cross paths perpendicular to each other as a means of minimizing communications interference. 

For walls less than 6 inches deep:

  • Creating a horizontal pathway for line voltage wiring.
  • For best results use a 7/8" Brad Point drill.
  • Create the path by using the built-in sidewall v-groove as a pilot hole.
  • Add an eXapath multi-purpose Nail Plate (EXNPSG-00) to protect installed wiring.
  • For additional stability fasten the nail plate to adjacent stud of blocking using holes provided.

Exterior walls of 6 inch depth or greater:

  • Route the line voltage wiring between the eXapath conduit and wall sheathing.
  • Provide at least 1 1/4" space between the cable and the  sheathing (check with building officials for local codes).
  • Line voltage wire may also be routed according to the recommendations above (walls less than 6 inches deep).

 eXapath Nail PLate and Brad Point DrilleXapath Nail Plate InstalledeXapath Nail Plate Installed with Video Cables